Time-tagged photon data (Photon-HDF5) from: Utilizing quantum fingerprints in plant cells to evaluate plant productivity
Data files
Oct 12, 2026 version files 685.55 MB
-
README.md
6.11 KB
-
TabQD585_c01.zip
425.58 MB
-
TabQD585_run550.zip
130.41 MB
-
TobQD585_2024-06-04.zip
129.55 MB
Abstract
This dataset contains time-tagged single-photon detection events from CdSe/ZnS quantum dots (emission 585 nm) internalized in Nicotiana tabacum (tobacco) leaves, recorded with a four-detector Hanbury Brown-Twiss setup under 80 MHz pulsed excitation and a Becker & Hickl DPC-230 time-to-digital converter (164.61 ps resolution). Each file holds one acquisition cycle in the open Photon-HDF5 format, with the absolute arrival time of every photon, the detector channel, and the delay relative to the laser reference. These data underlie the higher-order photon correlations g2(tau) ("quantum fingerprints") used for CNN-based classification of leaves in the associated article. The files can be reused to compute second- and higher-order photon correlation functions with arbitrary time binning, or to test alternative analysis and classification approaches. The data contain no human subject information and are released under CC0.
Ranasinghe, Stressinger, Xu, Sarhan, Harrington, Berry, Thomay, Analyst 2025, 150, 5394–5402, doi:10.1039/D5AN00326A
Contents
Photon arrival times from CdSe/ZnS quantum dots (585 nm) delivered into Nicotiana tabacum leaves, recorded with a four-detector Hanbury Brown–Twiss setup (80 MHz pulsed excitation, avalanche photodiodes) and a Becker & Hickl DPC-230 time-to-digital converter. One file per acquisition cycle.
The file name gives the measurement and the cycle number:
| File names | Files | Acquisition |
|---|---|---|
TobQD585_2024-06-04_c01.hdf5 … TobQD585_2024-06-04_c05.hdf5 |
5 | one continuous measurement, 5 cycles × 240 s, 2024-06-04 |
TabQD585_c01_c01.hdf5 … TabQD585_c01_c75.hdf5 |
75 | one continuous measurement, 75 cycles × 240 s, 2024-08-13 |
TabQD585_run550_c01.hdf5 … TabQD585_run550_c36.hdf5 |
36 | one continuous measurement (originally recorded as run550), 36 cycles of ~300 s |
Total: 116 files, 134 358 735 photons.
The three measurements are provided as separate archives (TobQD585_2024-06-04.zip, TabQD585_c01.zip, TabQD585_run550.zip); each contains this README, example_g2.py and the files of that measurement in Quantumdata/.
File format
Photon-HDF5 v0.5 (open HDF5-based format for time-tagged photon data).
| Field | Meaning |
|---|---|
photon_data/timestamps |
arrival time of each photon since the start of the cycle, integer ticks |
photon_data/timestamps_specs/timestamps_unit |
tick length in seconds (164.61 ps) |
photon_data/detectors |
detector channel of each photon: 4, 5, 8 or 9 |
photon_data/nanotimes |
delay of each photon after the preceding laser reference tick, in ticks of 164.61 ps; the last bin (user/dpc230/invalid_nanotime_marker) marks the few photons without a valid reference (48 in total; their timestamps are exact) |
setup/laser_repetition_rates |
measured rate of the laser-derived reference clock |
user/dpc230 |
acquisition and conversion details (original time unit, reference channel, reference period, number of reference ticks) |
Timestamps restart at zero in every cycle file.
Reading the data
The files open with any HDF5 tool, e.g. Python h5py or the Photon-HDF5 library phconvert. Example: cross-correlation histogram g²(τ) of detectors 4 and 5, summed over all cycles of one measurement (needs only numpy and h5py; run next to the Quantumdata/ folder as python example_g2.py TobQD585_2024-06-04, python example_g2.py TabQD585_c01 or python example_g2.py TabQD585_run550):
import glob
import sys
import h5py
import numpy as np
run = sys.argv[1] if len(sys.argv) > 1 else "TabQD585_c01" # measurement: TobQD585_2024-06-04, TabQD585_c01 or TabQD585_run550
det_a, det_b = 4, 5 # detector channels: 4, 5, 8, 9
tau_max, bin_ns = 100.0, 1.0 # +-100 ns, 1 ns bins
edges = np.arange(-tau_max, tau_max + bin_ns, bin_ns)
g2 = np.zeros(edges.size - 1)
for fname in sorted(glob.glob(f"Quantumdata/{run}_c*.hdf5")): # one file per acquisition cycle
with h5py.File(fname, "r") as f:
t = f["photon_data/timestamps"][:]
det = f["photon_data/detectors"][:]
unit = f["photon_data/timestamps_specs/timestamps_unit"][()]
a, b = t[det == det_a], t[det == det_b]
w = int(tau_max * 1e-9 / unit)
lo, hi = np.searchsorted(b, a - w), np.searchsorted(b, a + w)
dt = np.concatenate([b[l:h] - x for x, l, h in zip(a, lo, hi)]) * unit * 1e9 # ns
g2 += np.histogram(dt, bins=edges)[0]
for tau, n in zip(edges[:-1], g2):
print(f"{tau:7.1f} ns {int(n)}")
For TobQD585_2024-06-04 and TabQD585_c01 the histogram shows the 12.5 ns comb of the 80 MHz excitation laser; single cycles are too short for a visible signal. The same script is included as example_g2.py.
Provenance
Recorded with Becker & Hickl SPCM in FIFO mode (.spc files); decoded and converted to Photon-HDF5 without changing any photon time. Per-detector photon counts of every file were checked against an independent count of the original .spc files.
License
CC0 1.0
Development of quantum fingerprint
The photoluminescence (PL) of leaves was measured to confirm the emission of QDs. A Hanbury-Brown and Twiss (HBT) setup with four detectors was used to measure second-order correlation that describes the probability of detecting two photons at different times, providing information about the photon emission statistics. This work expands upon previous findings, where an HBT setup is employed to study photon correlation properties. Each path leads to an Avalanche Photodiode (APD). Every photon that arrives at the APD triggers a click recording the detection time. Higher-order correlation data were collected and analyzed using a machine learning model to classify the photon states.
Data processing: The raw Becker & Hickl FIFO files (.spc) recorded with the SPCM software were decoded and converted losslessly to the open Photon-HDF5 format (v0.5) using the open-source package phconvert. Each file corresponds to one SPCM acquisition cycle. The laser-derived reference channel was folded into per-photon nanotimes; its measured rate is stored as setup/laser_repetition_rates, and the original vendor settings and conversion statistics are stored under /user/dpc230.