Data from: Chemical speciation disparity underlies apparent preferential bioaccumulation of anthropogenic radioiodine in marine ecosystems
Data files
Oct 22, 2026 version files 59.39 KB
Abstract
Marine organisms strongly bioaccumulate radioiodine, making them highly vulnerable to nuclear contamination and critical for radiological risk assessments. Localized studies have revealed a counterintuitive anomaly that marine biota preferentially accumulate anthropogenic radioiodine over natural stable iodine. This apparent enrichment introduces profound uncertainties into radiological evaluations, yet its global extent and underlying mechanisms remain unresolved. Combining a global survey of biological isotopic signatures (129I/127I) with seawater speciation data, we demonstrate that this preferential bioaccumulation is a pervasive phenomenon across the global surface ocean. This enrichment arises not from isotopic fractionation, but because anthropogenic radioiodine predominantly enters the ocean as highly bioavailable iodide, whereas natural iodine exists mostly as less bioavailable iodate. Current radiological protection frameworks rely on total dissolved iodine, overlooking this critical speciation disparity. Consequently, existing models potentially underestimate actual radiation doses by up to two orders of magnitude, highlighting an urgent need to incorporate chemical speciation into risk assessments.
Dataset DOI: 10.5061/dryad.p2ngf1w67
Description of the data and file structure
This dataset contains iodine isotope data for marine biological samples and seawater samples used to evaluate radioiodine bioaccumulation in marine ecosystems. The biological dataset includes marine organisms collected from the North Pacific Ocean and other marine regions between 2012 and 2023. The seawater dataset includes total iodine and iodine species data from this study and previous oceanographic cruises, including KH-14-2, KH-17-3, MR21-04, and MR23-07.
Marine biological specimens include organisms from different trophic levels and body parts. Iodine was extracted from biological matrices using a staged pyro-hydrolysis system. Stable iodine concentrations were measured by Inductively Coupled Plasma Mass Spectrometry (ICP-MS), and 129I/127I atom ratios were measured by Accelerator Mass Spectrometry (AMS) at the University of Tokyo.
Dataset S1 also includes the seawater reference values used for comparison with each biological sample. These seawater references were added to document the provenance and matching status of the biota–seawater comparisons. They include information on seawater sampling time, station, location, depth, 129I/127I atom ratio, 129I concentration, data source, reference type, and comparison use. These fields distinguish co-collected or nearby seawater values from regional or literature-based reference values and clarify how each seawater reference was used in the analysis.
Files and variables
Files:
- Dataset_S1_Iodine_isotope_dataset_for_marine_biota.xlsx
- Dataset_S2_Iodine_isotope_dataset_for_seawater.xlsx
Dataset_S1_Iodine_isotope_dataset_for_marine_biota.xlsx
Variable description
Dataset_S1_Iodine_isotope_dataset_for_marine_biota.xlsx
-
Sample number: Unique identifier for each specimen (Integer).
-
Species name: Common or scientific name of the marine organism.
-
Trophic level: Ecological feeding position (Primary, Secondary, or Tertiary).
-
Sampling time: Time of collection (YYYY/MM/DD).
-
Latitude: Geographic latitude in decimal degrees (North is positive, South is negative).
-
Longitude: Geographic longitude in decimal degrees (East is positive, West is negative).
-
Sampling depth (m): Depth of sample collection in meters. Note: Blank cells indicate samples collected at the surface or depth data is not applicable.
-
Body part: Anatomical part analyzed (e.g., Gill, Muscle, Thyroid, Bulk, Stomach).
-
Sample dry weight (g dw): Weight of the dried sample in grams.
-
Total iodine (ppm): Concentration of stable iodine (127I) in parts per million (mg/kg dry weight).
-
Total iodine analytical uncertainty (1σ): Analytical uncertainty of the total iodine (127I) measurement.
-
129I/127I: Atom ratio of radioiodine (129I) to stable iodine (127I).
-
129I/127I analytical uncertainty (1σ): Analytical uncertainty of the 129I/127I atom ratio measurement.
-
129I (atoms/g dw): Concentration of radioiodine (129I) in atoms per gram of dry weight.
-
129I analytical uncertainty (1σ) (atoms/g dw): Analytical uncertainty of the 129I concentration measurement.
-
Seawater_sampling time: Sampling time or year of the seawater reference value used for comparison with the biological sample.
-
Seawater_station: Station name or identifier of the seawater reference sample.
-
Seawater_latitude: Geographic latitude of the seawater reference sample in decimal degrees.
-
Seawater_longitude: Geographic longitude of the seawater reference sample in decimal degrees.
-
Seawater_depth: Sampling depth of the seawater reference sample in meters.
-
Seawater_129I/127I: 129I/127I atom ratio of the seawater reference value.
-
Seawater_129I (atoms/L): 129I concentration of the seawater reference value, expressed as atoms per liter.
-
Reference: Source of the seawater reference value, such as this study or a literature source.
-
Reference_type: Type of seawater reference used for comparison, such as co-collected, nearby, regional, or literature-based reference.
-
Comparison_use: Purpose for which the seawater reference value was used in the analysis, such as regional comparison, biota-seawater comparison, or mechanistic comparison.
Dataset_S2_Iodine_isotope_dataset_for_seawater.xlsx
Variable description:
- Cruise: Identifier for the oceanographic expedition (e.g., KH-14-2).
- Time: Year of sample collection.
- Station: Identifier for the sampling location.
- Latitude: Geographic latitude in decimal degrees.
- Longitude: Geographic longitude in decimal degrees.
- Depth: Sampling depth in meters.
- TI 127I (µg/L): Total dissolved stable iodine (127I) concentration.
- TI 127I uncertainty (µg/L): Analytical uncertainty for TI 127I measurement.
- TI 129I (atoms/L): Total dissolved radioiodine (129I) concentration.
- TI 129I uncertainty (atoms/L): Analytical uncertainty for TI 129I measurement.
- TI ratio: Total atom ratio of 129I/127I.
- TI ratio uncertainty: Analytical uncertainty for the TI ratio.
- Iodide 127I (µg/L): Dissolved stable iodide (127I−) concentration.
- Iodide 127I uncertainty (µg/L): Analytical uncertainty for Iodide 127I.
- Iodide 129I (atoms/L): Dissolved radioiodine (129I−) concentration.
- Iodide 129I uncertainty (atoms/L): Analytical uncertainty for Iodide 129I.
- Iodide ratio: Atom ratio of 129I/127I in the iodide pool.
- Iodide ratio uncertainty: Analytical uncertainty for the iodide ratio.
- Iodate 127I (µg/L): Dissolved stable iodate (127IO3−) concentration.
- Iodate 127I uncertainty (µg/L): Analytical uncertainty for Iodate 127I.
- Iodate 129I (atoms/L): Dissolved radioiodine (129IO3−) concentration.
- Iodate 129I uncertainty (atoms/L): Analytical uncertainty for Iodate 129I.
- Iodate ratio: Atom ratio of 129I/127I in the iodate pool.
- Iodate ratio uncertainty: Analytical uncertainty for the iodate ratio.
- Reference: Source of the data (e.g., "This study" or specific citation).
Missing Values:
- Blank cells in "Sampling depth (m)" indicate that the depth information is not applicable for those specific samples. Blank cells in seawater reference fields indicate that no direct seawater reference was assigned for that item or that the information was not available from the source.