Data from: Comparative finite-element analysis: a single computational modeling method can reliably estimate the mechanical properties of porcine and human vertebrae

Robson Brown KA, Tarsuslugil S, Wijayathunga VN, Wilcox RK

Date Published: April 23, 2014

DOI: http://dx.doi.org/10.5061/dryad.db058

 

Files in this package

Content in the Dryad Digital Repository is offered "as is." By downloading files, you agree to the Dryad Terms of Service. To the extent possible under law, the authors have waived all copyright and related or neighboring rights to this data. CC0 (opens a new window) Open Data (opens a new window)

Title Load and displacement data for finite element models of human and pig vertebrae
Downloaded 35 times
Description Six porcine and four human cadaveric vertebrae were imaged using micro computed tomography (μCT) (Scanco μCT80, Scanco Medical, Switzerland) at a voxel size of 0.074 mm. Species-specific threshold values were then applied to segment the images of all of the specimens of each species. Each set of segmented images was then imported into an image processing software tool (ScanIP, Simpleware Ltd, Exeter) and downsampled to a resolution of 1 x 1 x 1 mm using an averaging method that allowed for partial volume effects. Each downsampled voxel represented the average of the binary segmented voxels within it and therefore the greyscale value of the downsampled voxel represented the BV/TV value of that region of the underlying bone. For all of the specimens, the regions were then imported into a FE meshing tool (ScanFE, Simpleware Ltd, Exeter) and a FE model of the vertebra and two end-caps was generated. An element size of approximately 1 mm was used because this had previously been shown to be sufficient for vertebral stiffness evaluation in specimens of a similar size and under similar conditions. A combination of hexahedral and tetrahedral linear elements were used to represent the vertebral geometry; in total each model contained between 200,000 and 400,000 elements. The cement region was assigned an elastic modulus of 2.45 GPa. Each element within the bone was assigned an elastic modulus based on BV/TV value derived from the downsampled voxel grayscale. All of the models were imported into a finite element software package (ABAQUS CAE version 6.9-1, Simulia Corp, USA). The models were solved and the specimen stiffness determined. To normalize for size, the ‘apparent modulus’ was also determined by multiplying the stiffness by the vertebral height and dividing by the cross sectional area. All the models were processed and the predicted vertebral stiffness was determined.
Download KRB_et_al_KCalculations.xlsx (29.01 Kb)
Details View File Details
Title Modelled stiffness and apparent modulus of porcine and human vertebral models for 5 loading modes
Downloaded 37 times
Description Six porcine and four human cadaveric vertebrae were imaged using micro computed tomography (μCT) (Scanco μCT80, Scanco Medical, Switzerland) at a voxel size of 0.074 mm. Species-specific threshold values were then applied to segment the images of all of the specimens of each species. Each set of segmented images was then imported into an image processing software tool (ScanIP, Simpleware Ltd, Exeter) and downsampled to a resolution of 1 x 1 x 1 mm using an averaging method that allowed for partial volume effects. Each downsampled voxel represented the average of the binary segmented voxels within it and therefore the greyscale value of the downsampled voxel represented the BV/TV value of that region of the underlying bone. For all of the specimens, the regions were then imported into a FE meshing tool (ScanFE, Simpleware Ltd, Exeter) and a FE model of the vertebra and two end-caps was generated. An element size of approximately 1 mm was used because this had previously been shown to be sufficient for vertebral stiffness evaluation in specimens of a similar size and under similar conditions. A combination of hexahedral and tetrahedral linear elements were used to represent the vertebral geometry; in total each model contained between 200,000 and 400,000 elements. The cement region was assigned an elastic modulus of 2.45 GPa. Each element within the bone was assigned an elastic modulus based on BV/TV value derived from the downsampled voxel grayscale. All of the models were imported into a finite element software package (ABAQUS CAE version 6.9-1, Simulia Corp, USA). The models were solved and the specimen stiffness determined. To normalize for size, the ‘apparent modulus’ was also determined by multiplying the stiffness by the vertebral height and dividing by the cross sectional area. All the models were processed and the predicted vertebral stiffness was determined. A series of virtual tests was then undertaken on the models generated with the species-specific threshold and the linear conversion factor. First, the height of the upper cement endcap was adjusted in all cases to be 40 % of the vertebral body height to ensure the loading point was always the same relative distance from the vertebra. The load was then applied to five positions equally spaced between the anterior and the posterior extent of the vertebral body. In each case, the model was solved and the vertebral stiffness determined as the load divided by the displacement at the point where the load was applied.
Download KRB_et_al_LoadingMode-PorcineHuman.xlsx (51.74 Kb)
Details View File Details

When using this data, please cite the original publication:

Robson Brown KA, Tarsuslugil S, Wijayathunga VN, Wilcox RK (2014) Comparative finite-element analysis: a single computational modeling method can reliably estimate the mechanical properties of porcine and human vertebrae. Journal of the Royal Society Interface 11(95): 20140186. http://dx.doi.org/10.1098/rsif.2014.0186

Additionally, please cite the Dryad data package:

Robson Brown KA, Tarsuslugil S, Wijayathunga VN, Wilcox RK (2014) Data from: Comparative finite-element analysis: a single computational modeling method can reliably estimate the mechanical properties of porcine and human vertebrae. Dryad Digital Repository. http://dx.doi.org/10.5061/dryad.db058