Title Raman spectroscopy investigation of chromium oxide coating
Downloaded 3 times
Description The raw data was generated with a thermo-scientific DXR Raman microscope using the Omnic software that was supplied with equipment.
Download Electronic file for figure 1 Raman Spectr...cm.pdf (485.1 Kb)
Details View File Details
Title FTIR investigation of chromium oxide coating
Downloaded 3 times
Description The raw data were generated with Nicolet is50 FTIR equipment using the omnic software that was supplied with the machine.
Download Electronic file for figure 2 The FTIR spe...cm.pdf (313.0 Kb)
Details View File Details
Title XPS Survey scan of chromium oxide coating
Downloaded 2 times
Description Scienta ESCA 300 spectrophotometer equipped with a monochromatic Al Kα (1486.6 ev) x-ray source were utilised for the measurements.
Download Electronic file for Figure 3 (a) Survey scan.pdf (626.5 Kb)
Details View File Details
Title XPS Cr2P doublet for chromium oxide coating
Downloaded 1 time
Description Scienta ESCA 300 spectrophotometer equipped with a monochromatic Al Kα (1486.6 ev) x-ray source were utilised for the measurements. The obtained XPS data was analysed with CasaXPS software, Shirkley method was used for the background subtraction and the binding energy calibration was implemented by using the C1s peak taking it as 285eV. A mixture of Gaussian and Lorentzian model was used in the fitting of the spectrum
Download Electronic file for Figure 3 (b) Cr2P doublet.pdf (208.6 Kb)
Details View File Details
Title XPS O1S peak for chromium oxide coating
Downloaded 1 time
Description Scienta ESCA 300 spectrophotometer equipped with a monochromatic Al Kα (1486.6 ev) x-ray source were utilised for the measurements. The obtained XPS data was analysed with CasaXPS software, Shirkley method was used for the background subtraction and the binding energy calibration was implemented by using the C1s peak taking it as 285eV.
Download Electronic file for Figure 3 (c) O1S peak.pdf (186.0 Kb)
Details View File Details
Title Structural characterization of chromium oxide coating using XRD
Downloaded 4 times
Description The raw data were generated with Siemens D5000 X-ray Diffractometer using Diffrac plus XRD commander software supplied with the machine
Download Electronic file for Figure 5 The XRD data...0W.pdf (736.6 Kb)
Details View File Details
Title Potentiodynamic polarisation curves of chromium oxide coated and uncoated stainless steel substrates in Ringers solution at 37
Downloaded 1 time
Description The experiment was performed with VoltaLab 40 PGZ301 manufactured by Radiometer analytical, France. VoltaMaster 4 software supplied with the equipment was used for data acquisition and analysis
Download Electronic file for Figure 6 Potentiodyna...37.pdf (733.8 Kb)
Details View File Details
Title EIS plots for chromium oxide coated and uncoated stainless steel in Ringers solution at 37 (a) Nyquist plots
Downloaded 4 times
Description The experiment was performed with VoltaLab 40 PGZ301 manufactured by Radiometer analytical, France. VoltaMaster 4 software supplied with the equipment was used for data acquisition and analysis.
Download Electronic file for Figure 8 EIS plots fo...ts.pdf (206.0 Kb)
Details View File Details
Title EIS plots for chromium oxide coated and uncoated stainless steel in Ringers solution at 37 (b) Bode plots (Magnitude versus frequency)
Downloaded 5 times
Description The experiment was performed with VoltaLab 40 PGZ301 manufactured by Radiometer analytical, France. VoltaMaster 4 software supplied with the equipment was used for data acquisition and analysis.
Download Electronic file for Figure 8 EIS plots fo...) .pdf (171.7 Kb)
Details View File Details
Title EIS plots for chromium oxide coated and uncoated stainless steel in Ringers solution at 37 (c) Bode plots (phase angle versus frequency)
Downloaded 1 time
Description The experiment was performed with VoltaLab 40 PGZ301 manufactured by Radiometer analytical, France. VoltaMaster 4 software supplied with the equipment was used for data acquisition and analysis.
Download Electronic file for Figure 8 EIS plots fo...y).pdf (168.0 Kb)
Details View File Details
Title Mott Schottky plots of chromium oxide coatings prepared at different oxygen flow rates in Ringers solution at 37
Downloaded 1 time
Description The experiment was performed with VoltaLab 40 PGZ301 manufactured by Radiometer analytical, France. VoltaMaster 4 software supplied with the equipment was used for data acquisition and analysis.
Download Electronic file for Figure 10.Mott Schott...37.pdf (118.9 Kb)
Details View File Details
Title Mott Schottky plot of uncoated stainless steel in Ringers solution at 37
Downloaded 5 times
Description The experiment was performed with VoltaLab 40 PGZ301 manufactured by Radiometer analytical, France. VoltaMaster 4 software supplied with the equipment was used for data acquisition and analysis.
Download Electronic file for Figure 11. Mott Schot...7 .pdf (111.3 Kb)
Details View File Details
Title chromium ion release in Ringers solution
Downloaded 10 times
Description A Perkin Elmer Analyst 300 Atomic absorption spectroscopy facility was used to probe the Ringer’s solution from the corrosion test for a determination of chromium ion concentrations released into the solution.
Download Electronic file for Figure 12 chromium io...on.pdf (101.2 Kb)
Details View File Details
Title Measured crack spacing for coating strained to 20 and 25 percent
Downloaded 1 time
Description The measured crack spacing obtained from substrate straining was analysed statistically using SPSS software to obtained the frequency distribution of the crack spacing. The observed crack distribution was fitted to the normal, lognormal and weibull probability distribution function. The function that gave the best fit was used to calculate the mean crack spacing of the coatings.
Download Electronic file for figure 14 Measured cr...nt.pdf (115.5 Kb)
Details View File Details
Title Fitting of the observed spacing distribution to various distribution functions
Downloaded 1 time
Description The measured crack spacing obtained from substrate straining was analysed statistically using SPSS software to obtained the frequency distribution of the crack spacing. The observed crack distribution was fitted to the normal, lognormal and weibull probability distribution function. The function that gave the best fit was used to calculate the mean crack spacing of the coatings.
Download Electronic file for figure 15 Fitting of ...ns.pdf (121.3 Kb)
Details View File Details
Title crack spacing frequency of chromium oxide in Ringers solution for 1 month
Downloaded 2 times
Description The measured crack spacing obtained from substrate straining was analysed statistically using SPSS software to obtained the frequency distribution of the crack spacing for the films exposed to Ringers solution for 1 month. The observed crack distribution was fitted to the normal, lognormal and weibull probability distribution function. The function that gave the best fit was used to calculate the mean crack spacing of the coatings exposed to Ringers solution.
Download Electronic data for figure 16 crack spaci...th.pdf (106.7 Kb)
Details View File Details
Title Observed spacing distribution at saturation in the chromium oxide films soaked in Ringers solution for 1 month
Downloaded 1 time
Description The measured crack spacing obtained from substrate straining was analysed statistically using SPSS software to obtained the frequency distribution of the crack spacing for the films exposed to Ringers solution for 1 month. The observed crack distribution was fitted to the normal, lognormal and weibull probability distribution function. The function that gave the best fit was used to calculate the mean crack spacing of the coatings exposed to Ringers solution.
Download Electronic data for figure 17 Observed sp...th.pdf (106.7 Kb)
Details View File Details
Title the change in interfacial shear strength for chromium oxide coatings exposed to Ringers solution for period of one month.
Downloaded 1 time
Description Adhesion strength was calculated using the relation adopted from shear-lag model which relate the mean crack spacing, fracture strength and thickness of the coating
Download Electronic file for Figure 19 showing the...h..pdf (112.6 Kb)
Details View File Details

When using this data, please cite the original publication:

Oje AM, Ogwu AA (2017) Chromium oxide coatings with the potential for eliminating the risk of chromium ion release in orthopaedic implants. Royal Society Open Science 4(7): 170218. http://dx.doi.org/10.1098/rsos.170218

Additionally, please cite the Dryad data package:

Ogwu AM, Oje AA (2017) Data from: Chromium oxide coatings with the potential for eliminating the risk of chromium ion release in orthopaedic implants. Dryad Digital Repository. http://dx.doi.org/10.5061/dryad.m6909
Cite | Share
Download the data package citation in the following formats:
   RIS (compatible with EndNote, Reference Manager, ProCite, RefWorks)
   BibTex (compatible with BibDesk, LaTeX)

Search for data

Be part of Dryad

We encourage organizations to: