Antegrade anterior column acetabulum fracture fixation with cannulated compression headless screws - A biomechanical study on standardized osteoporotic artificial bone

Data files

Jul 17, 2024 version files 540 B

Abstract

NOTICE: The original data files published on September 27, 2019, have been removed due to non-compliance with Dryad guidelines for publishing human subjects data.

**************

Purpose

Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw.

Methods

Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking.

Results

Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point.

Conclusion

From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.