This DATSETNAMEreadme.txt file was generated on YYYY-MM-DD by NAME GENERAL INFORMATION 1. Title of Dataset: Pre-clinical feasibility testing of Inspired Therapeutics NeoMate System 2. Author Information A. Principal Investigator Contact Information Name: Kurt A. Dasse, PhD Institution: Inspired Therapeutics LLC, Merritt Island, Florida, USA Address: 7309 S HIGHWAY A1A, Melbourne Beach, FL, USA Email: kdasse@inspiredtherapeuticsllc.com B. Associate or Co-investigator Contact Information Name: Gretel Monreal, PhD Institution: University of Louisville Address: 302 E. Muhammad Ali Blvd, room 411, Louisville, KY, USA Email: gretel.monreal@louisville.edu C. Alternate Contact Information Name: Steven C. Koenig, PhD Institution: University of Louisville Address: 302 E. Muhammad Ali Blvd, room 408, Louisville, KY, USA Email: steven.koenig@louisville.edu 3. Date of data collection (single date, range, approximate date) : 2021-01-01 - 2021-08-30 4. Geographic location of data collection : Louisville, KY, USA 5. Information about funding sources that supported the collection of the data: National Institutes of Health SBIR grant 1R43HL144214-01 (PI, Dasse) SHARING/ACCESS INFORMATION 1. Licenses/restrictions placed on the data: None 2. Links to publications that cite or use the data: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 3. Links to other publicly accessible locations of the data: N/A 4. Links/relationships to ancillary data sets: N/A 5. Was data derived from another source? yes/no A. If yes, list source(s): No 6. Recommended citation for this dataset: N/A DATA & FILE OVERVIEW 1. File List: 10 supplement data files MonrealKoenigSlaughter_Suppl_1.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (2400 mL volume) MonrealKoenigSlaughter_Suppl_2.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (2400 mL volume) MonrealKoenigSlaughter_Suppl_3.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (500 mL volume) MonrealKoenigSlaughter_Suppl_4.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (500 mL volume) MonrealKoenigSlaughter_Suppl_5.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (300 mL volume) MonrealKoenigSlaughter_Suppl_6.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (300 mL volume) MonrealKoenigSlaughter_Suppl_7.xls - Intrinsic parameter data for NeoMate Systems A and B in Static Mock Flow Loop, Dynamic Mock Flow Loop, Acute Animal models MonrealKoenigSlaughter_Suppl_8.xls - Hemodynamic data for NeoMate Systems A and B in Dynamic Mock Flow Loop model (2400 ml volume) MonrealKoenigSlaughter_Suppl_9.xls - Hemodynamic data for NeoMate Systems A (sheep-1) and B (sheep 2) MonrealKoenigSlaughter_Suppl_10.xls - Blood parameter data for NeoMate Systems A (sheep-1) and B (sheep 2) 2. Relationship between files, if important: N/A 3. Additional related data collected that was not included in the current data package: N/A 4. Are there multiple versions of the dataset? yes/no No A. If yes, name of file(s) that was updated: i. Why was the file updated? ii. When was the file updated? METHODOLOGICAL INFORMATION 1. Description of methods used for collection/generation of data: Methods described in Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 2. Methods for processing the data: Methods described in Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 3. Instrument- or software-specific information needed to interpret the data: Microsoft Excel 4. Standards and calibration information, if appropriate: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 5. Environmental/experimental conditions: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 6. Describe any quality-assurance procedures performed on the data: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 7. People involved with sample collection, processing, analysis and/or submission: Gretel Monreal, Steven C Koenig, Mark S Slaughter, Gino F Morello, Steven R Prina, Landon H Tompkins, Jiapeng Huang, Barry N Gellman, Kurt A Dasse. DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_1.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A 1. File List: 10 supplement data files MonrealKoenigSlaughter_Suppl_1.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (2400 mL volume) MonrealKoenigSlaughter_Suppl_2.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (2400 mL volume) MonrealKoenigSlaughter_Suppl_3.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (500 mL volume) MonrealKoenigSlaughter_Suppl_4.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (500 mL volume) MonrealKoenigSlaughter_Suppl_5.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (300 mL volume) MonrealKoenigSlaughter_Suppl_6.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (300 mL volume) MonrealKoenigSlaughter_Suppl_7.xls - Intrinsic parameter data for NeoMate Systems A and B in Static Mock Flow Loop, Dynamic Mock Flow Loop, Acute Animal models MonrealKoenigSlaughter_Suppl_8.xls - Hemodynamic data for NeoMate Systems A and B in Dynamic Mock Flow Loop model (2400 ml volume) MonrealKoenigSlaughter_Suppl_9.xls - Hemodynamic data for NeoMate Systems A (sheep-1) and B (sheep 2) MonrealKoenigSlaughter_Suppl_10.xls - Blood parameter data for NeoMate Systems A (sheep-1) and B (sheep 2) 2. Relationship between files, if important: N/A 3. Additional related data collected that was not included in the current data package: N/A 4. Are there multiple versions of the dataset? yes/no No A. If yes, name of file(s) that was updated: i. Why was the file updated? ii. When was the file updated? METHODOLOGICAL INFORMATION 1. Description of methods used for collection/generation of data: Methods described in Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 2. Methods for processing the data: Methods described in Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 3. Instrument- or software-specific information needed to interpret the data: Microsoft Excel 4. Standards and calibration information, if appropriate: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 5. Environmental/experimental conditions: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 6. Describe any quality-assurance procedures performed on the data: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 7. People involved with sample collection, processing, analysis and/or submission: Gretel Monreal, Steven C Koenig, Mark S Slaughter, Gino F Morello, Steven R Prina, Landon H Tompkins, Jiapeng Huang, Barry N Gellman, Kurt A Dasse. DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_1.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A 1. File List: 10 supplement data files MonrealKoenigSlaughter_Suppl_1.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (2400 mL volume) MonrealKoenigSlaughter_Suppl_2.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (2400 mL volume) MonrealKoenigSlaughter_Suppl_3.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (500 mL volume) MonrealKoenigSlaughter_Suppl_4.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (500 mL volume) MonrealKoenigSlaughter_Suppl_5.xls - Hydrodynamic (HQ) data for NeoMate System A (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (300 mL volume) MonrealKoenigSlaughter_Suppl_6.xls - Hydrodynamic (HQ) data for NeoMate System B (500-5000 rpm, 500 rpm increments)in Static Mock Flow Loop model (300 mL volume) MonrealKoenigSlaughter_Suppl_7.xls - Intrinsic parameter data for NeoMate Systems A and B in Static Mock Flow Loop, Dynamic Mock Flow Loop, Acute Animal models MonrealKoenigSlaughter_Suppl_8.xls - Hemodynamic data for NeoMate Systems A and B in Dynamic Mock Flow Loop model (2400 ml volume) MonrealKoenigSlaughter_Suppl_9.xls - Hemodynamic data for NeoMate Systems A (sheep-1) and B (sheep 2) MonrealKoenigSlaughter_Suppl_10.xls - Blood parameter data for NeoMate Systems A (sheep-1) and B (sheep 2) 2. Relationship between files, if important: N/A 3. Additional related data collected that was not included in the current data package: N/A 4. Are there multiple versions of the dataset? yes/no No A. If yes, name of file(s) that was updated: i. Why was the file updated? ii. When was the file updated? METHODOLOGICAL INFORMATION 1. Description of methods used for collection/generation of data: Methods described in Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 2. Methods for processing the data: Methods described in Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 3. Instrument- or software-specific information needed to interpret the data: Microsoft Excel 4. Standards and calibration information, if appropriate: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 5. Environmental/experimental conditions: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 6. Describe any quality-assurance procedures performed on the data: Monreal et al, PLOS One, PONE-D-21-33348R2, accepted for publication 2022. 7. People involved with sample collection, processing, analysis and/or submission: Gretel Monreal, Steven C Koenig, Mark S Slaughter, Gino F Morello, Steven R Prina, Landon H Tompkins, Jiapeng Huang, Barry N Gellman, Kurt A Dasse. DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_1.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_2.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_3.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_4.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_5.xls] 1. Number of variables: 6 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_6.xls] 1. Number of variables: 7 measured (P1, P2, P3, P4, P5, P6), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 18 columns, 11 rows, 10 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: P1 (mmHg) - pressure measured at pump outflow P2 (mmHg) - pressure measured at inlet to pump outflow cannula P3 (mmHg) - pressure measured at outlet of pump outflow cannula P4 (mmHg) - pressure measured at inlet to pump inflow cannula P5 (mmHg) - pressure measured at outlet of pump inflow cannula P6 (mmHg) - pressure measured at pump inflow Flow (L/min) - measured outflow of NeoMate centrifugal pump 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_7.xls] 1. Number of variables: 7 measured (V VCA, V motor, POS VCA, I motor, TACH, Temp VCA, Temp motor), 1 control (Q or flow), and 3 calculated (P1-P6, P2-P3, and P4-P5) 2. Number of cases/rows: 8 columns, 33 rows, 8 folders (NeoMate pump speeds of 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm) 3. Variable List: V VCA (volts) - Voice Coil Actuator V motor (volts) - Pump Motor POS VCA (volts) - Position of the Voice Coil Actuator I motor (amps) - motor current TACH (volts) - conversion to speed (rpm) of impeller Temp VCA (Celsius degrees) - temperature of Voice Coil Actuator Temp motor (Celsius degrees) - temperature of pump motor Power (watts) - calculated from motor and VCA voltage and current 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_8.xls] 1. Number of variables: 12 measured (pump inflow pressure, pump outflow pressure, maximum left ventricular pressure, minimum left ventricular pressure, end-diastolic ventricular pressure, systolic aortic pressure, diastolic aortic pressure, mean aortic pressure, venous pressure, pump flow, aortic flow) and 2 calculated (pump outflow pressure - pump inflow pressure, total flow = pump flow + aortic flow) 2. Number of cases/rows: 13 columns, 15 rows, 2 folders for NeoMate controller A (dynamic mock flow loop model) and NeoMate controller B (dynamic mock flow loop model) at pump speeds of 0, 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 rpm 3. Variable List: Pump inflow (mmHg) Pump outflow (mmHg) ΔP pump (mmHg) = pump outflow (mmHg) - pump inflow (mmHg) LV pressure max (mmHg) = maximum left ventricular pressure LV pressure min (mmHg) = minimum left ventricular pressure LV end-diastolic pressure (mmHg) = left ventricular end-diastolic pressure LV pressure mean (mmHg) = mean left ventricular pressure Aortic pressure systolic (mmHg) = aortic systolic pressure Aortic pressure diastolic (mmHg) = aortic diastolic pressure Aortic pressure mean (mmHg) = aortic mean pressure Venous pressure (mmHg) Pump flow (L/min) = mean pump flow Aortic flow (L/min) = mean aortic flow Total flow (L/min) = mean pump flow (L/min) + mean aortic flow (L/min) 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_9.xls] 1. Number of variables: 12 measured (pump inflow pressure, pump outflow pressure, maximum left ventricular pressure, minimum left ventricular pressure, mean left ventricular pressure, end-diastolic ventricular pressure, systolic aortic pressure, diastolic aortic pressure, mean aortic pressure, aortic pulse pressure, left atrial pressure, central venous pressure, heart rate, pump flow, pulmonary artery flow) 2. Number of cases/rows: 11 columns, 16 rows, 2 folders for NeoMate controller A (sheep-1) and NeoMate controller B (sheep-2) at pump speeds of 0, 3000, 4000, and 5000 rpm 3. Variable List: P pump in (mmHg) = pump inflow pressure P pump out (mmHg) = pump outflow pressure LVP max (mmHg) = maximum left ventricular pressure LVP min (mmHg) = minimum left ventricular pressure LVP mean (mmHg) = mean left ventricular pressure LVEDP (mmHg) = left ventricular end-diastolic pressure AoP sys (mmHg) = aortic systolic pressure AoP dia (mmHg) = aortic diastolic pressure AoP mean (mmHg) = mean aortic pressure AoP, Pulse P (mmHg) = aortic pulse pressure = maximum aortic pressure (mmHg) - minimum aortic pressure (mmHg) LAP (mmHg) = mean left atrial pressure CVP (mmHg) = mean central venous pressure Carotid P (mmHg) = mean carotid artery pressure HR (bpm) = heart rate Q pump (L/min) = mean pump flow Q PA (L/min) = mean pulmonary artery flow 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A DATA-SPECIFIC INFORMATION FOR: [FILENAME = MonrealKoenigSlaughter_Suppl_10.xls] 1. Number of variables: 14 measured (Na+, K+, Ca2+, Glu, Hct, Hgb, pH, pCO2, pO2, TCO2, HCO3, BE, sO2, PfHb) 2. Number of cases/rows: 8 columns, 15 rows, 2 folders for NeoMate controller A (sheep-1) and NeoMate controller B (sheep-2) at pump speeds of 0, 3000, 4000, and 5000 rpm 3. Variable List: Na+ (mmol/L) - Sodium K+ (mmol/L) - Potassium Ca2+ (mmol/L) - Calcium Glu (mg/dL) - Glucose Hct (% PCV) - Hematocrit Hg (g/dL) - Hemoglobin pH (unitless) pCO2 (mmHg) - partial pressure of Carbon Dioxide pO2 (mmHg) - partial pressure of Oxygen TCO2 (mmol/L) - total Carbon Dioxide HCO3 (mmol/L) - Bicarbonate BE (mmol/L) - Base Excess sO2 (%) - Sulfur Dioxide PfHb (mg/dL) - Plasma Free Hemoglobin 4. Missing data codes: N/A n 5. Specialized formats or other abbreviations used: N/A