Data from: A surface acoustic wave (SAW)-based lab-on-chip for the detection of active α-glycosidase
Data files
Dec 22, 2022 version files 873.96 KB
- 
              
                BRAIKER_negative_control_shifts.txt
                246 B
- 
              
                BRAIKER_shifts_master_curve.txt
                489 B
- 
              
                QCM_probe_dissipation_0.15U-mL.csv
                69.88 KB
- 
              
                QCM_probe_dissipation_1.5U-mL.csv
                70.76 KB
- 
              
                QCM_probe_dissipation_150U-mL.csv
                38.48 KB
- 
              
                QCM_probe_dissipation_15U-mL.csv
                59.44 KB
- 
              
                QCM_probe_dissipation_shifts.txt
                902 B
- 
              
                QCM_probe_frequency_0.15U-mL.csv
                75.09 KB
- 
              
                QCM_probe_frequency_1.5U-mL.csv
                76 KB
- 
              
                QCM_probe_frequency_150U-mL.csv
                41.29 KB
- 
              
                QCM_probe_frequency_15U-mL.csv
                63.31 KB
- 
              
                QCM_probe_frequency_shifts.txt
                946 B
- 
              
                QCM_sample_dissipation_0.15U-mL.csv
                42.88 KB
- 
              
                QCM_sample_dissipation_1.5U-mL.csv
                49.99 KB
- 
              
                QCM_sample_dissipation_150U-mL.csv
                60.72 KB
- 
              
                QCM_sample_dissipation_15U-mL.csv
                25.25 KB
- 
              
                QCM_sample_frequency_0.15U-mL.csv
                43.47 KB
- 
              
                QCM_sample_frequency_1.5U-mL.csv
                51.41 KB
- 
              
                QCM_sample_frequency_150U-mL.csv
                65.05 KB
- 
              
                QCM_sample_frequency_15U-mL.csv
                26.08 KB
- 
              
                README.md
                9.97 KB
- 
              
                UV_inhibition_assay.txt
                360 B
- 
              
                UV_maltoside_assay.txt
                1.95 KB
Abstract
UV data were acquired via UV-Vis spectroscopy with a JASCO V550 spectrophotometer (JASCO Europe, Cremello, Italy); the raw data were used without any further processing.
QCM data were acquired with a QCM-D E4 model (Q-Sense AB, Sweden); the raw data were processed by MATLAB to eliminate any offset or drift.
SAW-LoC data were acquired with a vectorial network analyzer E5071C (Agilent Technologies) connected to an RF switch 34980A (Agilent Technologies); an in-house software based on LabView® is used to pilot the RF-switch and the vectorial network analyzer.
Data files are uploaded as Plain text or as .csv files. The .csv files can be opened with Microsoft Excel or Google Sheets.