Data from: Implementation of an automated early warning scoring system in a surgical ward: practical use and effects on patient outcomes

Mestrom E, De Bie A, van de Steeg M, Driessen M, Atallah L, Bezemer R, Bouwman RA, Korsten E

Date Published: May 14, 2019

DOI: https://doi.org/10.5061/dryad.000mn47

Files in this package

Content in the Dryad Digital Repository is offered "as is." By downloading files, you agree to the Dryad Terms of Service. To the extent possible under law, the authors have waived all copyright and related or neighboring rights to this data. CC0 (opens a new window) Open Data (opens a new window)

Title Clinical outcomes
Downloaded 15 times
Description This data file describes the clinical data of both control and intervention group. The last columns describe the number and percentage of corresponding measurements in both the data retrieved from the automated EWS system, as well as from the electronic patient records (EMR). This was only applicable for cases in the intervention period since both methods (automated EWS system and EMR) were used.
Download README.txt (1.686 Kb)
Download Automated_EWS_implementation_Mestrom_Bie_C....xlsx (92.86 Kb)
Details View File Details
Title Measurements_control_period
Downloaded 13 times
Description This dataset contains every measurement of vital sign(s) recorded in the electronic medical record during the control period.
Download README.txt (1.042 Kb)
Download Automated_EWS_implementation_Mestrom_Bie_M....xlsx (528.2 Kb)
Details View File Details
Title Measurements_intervention_period_EMR
Downloaded 13 times
Description This dataset contains every measurement of vital sign(s) recorded in the electronic medical record during the intervention period.
Download README.txt (948 bytes)
Download Automated_EWS_implementation_Mestrom_Bie_M....xlsx (497.9 Kb)
Details View File Details
Title Measurements_intervention_period_EWS_system
Downloaded 10 times
Description This dataset contains every measurement of vital sign(s) recorded in automated EWS system during the intervention period.
Download README.txt (1.04 Kb)
Download Automated_EWS_implementation_Mestrom_Bie_M....xlsx (229.5 Kb)
Details View File Details

When using this data, please cite the original publication:

Mestrom E, De Bie A, van de Steeg M, Driessen M, Atallah L, Bezemer R, Bouwman RA, Korsten E (2019) Implementation of an automated early warning scoring system in a surgical ward: Practical use and effects on patient outcomes. PLOS ONE 14(5): e0213402. https://doi.org/10.1371/journal.pone.0213402

Additionally, please cite the Dryad data package:

Mestrom E, De Bie A, van de Steeg M, Driessen M, Atallah L, Bezemer R, Bouwman RA, Korsten E (2019) Data from: Implementation of an automated early warning scoring system in a surgical ward: practical use and effects on patient outcomes. Dryad Digital Repository. https://doi.org/10.5061/dryad.000mn47
Cite | Share
Download the data package citation in the following formats:
   RIS (compatible with EndNote, Reference Manager, ProCite, RefWorks)
   BibTex (compatible with BibDesk, LaTeX)

Search for data

Be part of Dryad

We encourage organizations to: