Skip to main content
Dryad

Data from: A simple micropump based on a freeze-dried superabsorbent polymer for multiplex solution processing in disposable devices

Cite this dataset

Biswas, Gokul Chandra; Rana, Md. Mohosin; Kazuhiro, Takekoshi; Suzuki, Hiroaki (2019). Data from: A simple micropump based on a freeze-dried superabsorbent polymer for multiplex solution processing in disposable devices [Dataset]. Dryad. https://doi.org/10.5061/dryad.57k73c3

Abstract

We describe a simple micropump for disposable microfluidic devices. The pump is constructed using a freeze-dried disc of a superabsorbent polymer (SAP). The disc absorbs a solution in a flow channel and swells upward in a pumping chamber. Despite the simple structure of this device, the rate of absorption remains constant and can be adjusted by changing the composition of the SAP, its size, the dimensions of the flow channel, and the medium to be absorbed. The pumping action can be initiated by applying an electrical signal using a switchable hydrophobic valve. The integrated approach of SAP pump and switchable valve could facilitate the automatic processing of many solutions required for bioassay.

Usage notes